Filter Results By:

Products

Applications

Manufacturers

Modulation Meters

Meters that measure the process, or result of the process, of varying a characteristic of a carrier, in accordance with an information-bearing signal. (atis.org)

See Also: Modulation, Optical Modulation, Modulation Analysis, Modulation Analyzers, MER


Showing results: 16 - 22 of 22 items found.

  • E-Series Average Power Sensor

    E9301B - Keysight Technologies

    Measure the average power of all modulation formats Wide dynamic range power measurements from -30 dBm to +44 dBm10 MHz to 6 GHz frequency coverage for Wireless Comms formats Low SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters

  • E-Series Average Power Sensor

    E9301A - Keysight Technologies

    Measure the average power of all modulation formats Wide dynamic range (-60 dBm to +20 dBm) and frequency range 10 MHz to 6 GHzHigh maximum power specification Low SWR for reducing mismatch uncertainty Calibration factors linearity and temperative compensation data stored in EEPROM Fast measurement speeds (up to 400 readings per second with the Keysight E4416A)Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters

  • PWM Type AC Power Supply

    LSP-5KVA - Lisun Electronics Inc.

    • Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is  0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter  Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%

  • Terminal Power Meter

    TPM-50A - ShinewayTech

    ShinewayTech@ TPM-50A Terminal Power meter can test (1) Average power range: -40 dBm~+20 dBm;(3) Modulation bandwidth: 5MHz;(3) Continuous signal and burst signal test. Highly accurate power measurement CW and digital modulated signal (For example: GSM/EDGE, CDMA/EV-DO, WCDMA/HSDPA, WiMAX, and TD-SCDMA). It is very important to test that if the transmitter is at a specified level or not. For example, the tester needs to test the output power of base station. Because the lower output power produces the larger coverage area to cause call interruption.

  • Network Analyzer

    DPNA-6G AXIe - Holding Informtest

    The AXI DPNA-6G module is the world's first network analyzer in the form factor of the AXIe-1 module, as well as the first Russian device that meets the AXIe-1 standard. In the mode of the network parameters meter, the AXI DPNA-6G module measures the vector values ​​of the network parameters on two ports: transmission coefficients (S12, S21) and reflection (S11, S22). At the same time, all necessary types of calibrations are supported: one- and two-port short-circuit, XX, matched load, transmission normalization. The software supports the import of third party calibration standard parameters. In the measuring receiver mode, the module provides:*generation of a harmonic signal (frequency synthesizer);*spectrum analyzer and power level in a given band;*measuring the frequency of a known signal;*measurement of analog modulation parameters;*phase noise measurement.

  • SNR Noise Generator

    CNG-EbNo - Noisecom

    The CNG-EbNo is a fully automated precision signal to noise (AWGN) generator that sets, and maintains a highly accurate ratio between a user supplied carrier and internally generated noise, over a wide range of signal power levels and frequencies. The internal AWGN meter provides repeatable SNR waveforms for accurate signal generation. The instrument gives system, design, and test engineers in the telecommunications industry a single tool to generate precision signal to noise ratios. These signals are used to compare theoretical BER to SNR ratios, found in "waterfall" type graphs, with measured values from the DUT to evaluate different modulation schemes. Users can obtain higher yield through automated testing, plus increased confidence from repeatable, accurate test results. Standard units can be modified for specific customer requirements. Please consult the factory for pricing and availability of these requests.

  • Function Generators

    Shanghai MCP Corp

    Respective dual channels function/arbitrary waveform generator. Sine wave output up to 160MHz, full-band resolution of 1μHz. Pulse waveform up to 50MHz (or 40MHz), adjustable time of rising, falling and duty ratio. Sampling rate of 500MSa/s and vertical resolution of 16bit. 6-bit high-precision frequency meter compatible with TTL level signal. Arbitrary wave storage of 8~32M points, 7GB non-volatile waveform storage. Multi modulation function::AM,FM,PM, ASK,FSK,PSK, BPSK, QPSK,OSK,PWM, QAM, SUM . 16bit digital arbitrary wave (TTL level) DARB. 16th Harmonic Generation Function. Protocol output: I2C, SPI, UART (TTL level). 8 Inch high-resolution TFT color LCD,WVGA(800×480). Standard interface: USB Host, USB Device, LAN, 10MHz clock source input/output. Frequency sweep and burst output. Easy-to-use multi-functional knob and numeric keypad